1.
Alerta (San Salvador) ; 7(1): 42-49, ene. 26, 2024. graf, tab
Article in Spanish | BISSAL, LILACS | ID: biblio-1526703

ABSTRACT

Introducción. El Síndrome del túnel carpiano es la neuropatía periférica compresiva más común de la extremidad superior, que se produce por la compresión del nervio mediano. Los casos leves y moderados pueden tratarse con métodos conservadores como ultrasonido terapéutico o infiltración con corticoesteroides. Objetivo. Describir la evolución clínica de pacientes con síndrome de túnel carpiano tratados con terapia por ultrasonido e infiltración de corticoesteroides. Metodología. Ensayo clínico abierto, en pacientes con síndrome del túnel carpiano leve y moderado, que consultaron del 1 de octubre 2021 al 30 de mayo 2022. Se formaron dos grupos; el que recibió tratamiento con ultrasonido con 12 casos y el grupo tratado con infiltración con corticoesteroides con seis casos. Ambos grupos fueron intervenidos en la consulta inicial, y luego, en las cuatro y ocho semanas posteriores al inicio del tratamiento. Resultados. Se muestran los resultados descriptivos relacionados con la intensidad de dolor, valorada con la Escala Visual Numérica, la infiltración obtuvo dos casos sin dolor y cuatro con dolor moderado, contrario a ultrasonido que se mantuvo con cuatro casos leves, tres moderados y cinco intensos. En los síntomas, la infiltración redujo el número de casos en cuatro de los síntomas estudiados, en cambio el ultrasonido únicamente en dos. En severidad, valorada con el cuestionario de Boston para túnel carpal, con infiltración se obtuvieron dos casos asintomáticos y ninguno con ultrasonido. Respecto a los signos clínicos, el signo de Tinel desapareció en cuatro casos en ambos grupos, mientras que signo de Phalen desapareció en cuatro casos en ultrasonido y dos en infiltración. Conclusión. En intensidad de dolor y grado de severidad, la infiltración generó casos asintomáticos y redujo mayor cantidad de síntomas que el ultrasonido. Ambos tratamientos disminuyeron la presencia de signos clínicos


Introduction. Carpal tunnel syndrome is the most common compressive peripheral neuropathy of the upper extremity, which is caused by compression of the median nerve. Mild and moderate cases can be treated with conservative methods such as therapeutic ultrasound or corticosteroid infiltration. Objective. To describe the clinical evolution of patients with carpal tunnel syndrome treated with ultrasound therapy and corticosteroid infiltration. Methodology. A prospective open clinical trial was conducted in patients with mild and moderate carpal tunnel syndrome who consulted from October 1, 2021 to May 30, 2022. Two groups were formed: the group that received ultrasound treatment with 12 cases and the group treated with corticosteroid infiltration with six cases. Both groups were treated at the initial consultation and then at four and eight weeks after the start of treatment. Results. The descriptive results related to the intensity of pain, evaluated with the Visual Numeric Scale, are shown. Infiltration obtained two cases without pain and four with moderate pain, contrary to ultrasound which was maintained with four mild, three moderate and five intense cases. In symptoms, infiltration reduced the number of cases in four of the symptoms studied, while ultrasound reduced the number of cases in only two. In severity, assessed with the Boston carpal tunnel questionnaire, with infiltration, there were two asymptomatic cases and none with ultrasound. Regarding clinical signs, Tinel's sign disappeared in four cases in both groups, while Phalen's sign disappeared in four cases in ultrasound and two in infiltration. Conclusion. Infiltration produced asymptomatic patients and reduced more symptoms than ultrasonography in terms of pain intensity and severity. Clinical symptoms were less common with both treatments.


Subject(s)
El Salvador
2.
BrJP ; 6(4): 374-382, Oct.-Dec. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527982

ABSTRACT

ABSTRACT BACKGROUND AND OBJECTIVES: Wound complications and pharmacological pain relief methods used at the skin surgical site after cesarean delivery may result in women's physical and emotional burden. Thus, nonpharmacological treatments must be explored to avoid these complications and side effects on maternal health. The objective of this study was to investigate the effects of Combined Ultrasound and Electric Field Stimulation (CUSEFS) on cicatricial pain and functional capacity in immediate cesarean delivery. METHODS: This study has a randomized clinical trial, double-blind, and placebo-controlled design. Thirty women (25.7±5.0 years) in immediate postpartum were randomly assigned to three groups: Control (CG, n:9), CUSEFS (TG, n:11), and Placebo (PG, n:10). CUSEFS was performed once for 20 minutes. Cicatricial pain (McGill Pain Questionnaire) and functional capacity (Functional Capacity Check) was assessed at baseline, after the intervention, and after 30 minutes. Cohen's (d) and Mixed-design analysis of variance were used to compare groups. RESULTS: Immediately after the intervention, TG showed a decrease in cicatricial pain compared with CG in sensory (d:3.8 to 4.0), affective (d:4.0), and total categories (d:3.9). In functional capacity, TG had less difficulty than CG at walking (d:0.6) and lying down (d:1.1), and PG at rest (d: 0.9). CONCLUSION: CUSEFS might be a resource for managing cicatricial pain and functional capacity in immediate cesarean delivery. Further studies with longer duration and different CUSEFS doses/parameters are required.


RESUMO JUSTIFICATIVA E OBJETIVOS: As complicações na ferida e o uso de métodos farmacológicos de alívio da dor no local cirúrgico após a cesariana podem resultar em sobrecarga física e emocional para a mulher. Assim, tratamentos não farmacológicos devem ser explorados para evitar essas complicações e efeitos adversos à saúde materna. O objetivo deste estudo foi investigar os efeitos da terapia combinada de estimulação elétrica por meio do ultrassom (CUSEFS) na dor cicatricial e na capacidade funcional no pós-parto imediato de cesariana. MÉTODOS: Este estudo possui um desenho de ensaio clínico randomizado, duplo-cego e controlado por placebo. Trinta mulheres (25,7±5,0 anos) em pós-parto imediato de cesariana foram distribuídas aleatoriamente em três grupos: Controle (CG, n:9), CUSEFS (TG:11) e Placebo (PG, n:10). O CUSEFS foi realizado uma vez por 20 minutos. A dor cicatricial (Questionário de Dor McGill) e a capacidade funcional (Functional Capacity Check) foram avaliadas no início, após a intervenção e após 30 minutos. As análises de variância de design misto e Cohen (d) foram usadas para comparar os grupos. RESULTADOS: Imediatamente após a intervenção, o TG apresentou diminuição na dor cicatricial em relação ao CG nas categorias sensorial (d:3,8 a 4,0), afetiva (d:4,0) e total (d:3,9). Na capacidade funcional, o TG apresentou menor dificuldade que o CG na marcha (d:0,6) e deitado (d:1,1), e que o PG em repouso (d:0,9). CONCLUSÃO: O CUSEFS pode ser um recurso para o manejo da dor cicatricial e da capacidade funcional imediatamente após a cesariana. Além disso, são necessários mais estudos com maior duração e diferentes doses/parâmetros de CUSEFS.

3.
Acta fisiátrica ; 30(1): 69-72, mar. 2023.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1434957

ABSTRACT

Não há dúvidas sobre os prejuízos na vida humana, extensivos à família e sociedade como um todo, abrangendo todos os aspectos funcionais das pessoas envolvidas, além do indivíduo, originados dos traumatismos cranioencefálico, agudos e crônicos, externos ou internos: acidentes, atropelamentos, quedas, crimes, acidente vascular cerebral, doenças com neurodegeneração progressiva, resultando em estados demenciais. Ao longo de meio século, houve a introdução contínua de medicamentos, com resultados usualmente contraditórios e frustrantes, exigindo novas tentativas com outras classes farmacológicas. No todo, a limitação se faz sentir na impossibilidade de reversão ou mesmo de mera estabilização dos danos neurológicos, e inocuidade em termos de estimulação da neuroplasticidade. Uma exceção parece ser uma nova abordagem: a estimulação cerebral profunda por pulsos sonoros de baixa frequência (Transcranial Pulse Stimulation, ou TPS). Ainda pouco conhecida, a não ser em alguns centros de tratamento, tem se mostrado ser um acréscimo válido, por complementar os programas multidisciplinares de reabilitação


There is no doubt about the damage to human life, also extended to family and society as a whole, regarding all the functional aspects of those involved, not only the patient itself, which originates from traumatic brain injury, acute or chronic, for external or internal reasons, such as accidents, run overs, falls, crimes, stroke, progressive neurodegenerative diseases that result in dementia states. Over half a century, drugs have been continuously introduced, however their results have constantly been contradictory and frustrating, requiring new attempts with other pharmacological classes. Overall, the limitation is felt in the impossibility of reversing or even merely stabilizing the neurological damage and inefficacy regarding neuroplasticity stimulation. One exception seems to be a new approach, the non-invasive brain stimulation by low-frequency sound pulses (Transcranial Pulse Stimulation, or TPS). Except for some treatment centers, TPS is still unknown, however it has shown to be a valid adjunct in multidisciplinary rehabilitation programs

4.
Rev. Flum. Odontol. (Online) ; 1(60): 137-146, jan.-abr. 2023. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1411348

ABSTRACT

Introdução: O aumento da expectativa média de vida leva a população a buscar, com maior frequência, tratamentos estéticos que visem o rejuvenescimento da face e do pescoço. O Ultrassom microfocado (MFU) é descrito como uma opção de tratamento não-invasiva para a flacidez facial e o envelhecimento. Objetivo: Revisar a literatura científica quanto ao uso do MFU no processo de rejuvenescimento facial e correção da flacidez da pele. Metodologia: Trata-se de uma revisão narrativa da literatura, baseada na pesquisa de artigos científicos nas bases de dados PubMed e Biblioteca Virtual em Saúde realizada durante o mês de março de 2022, através da seguinte estratégia de busca: "Microfocused Ultrasound AND Facial Rejuvenation AND Skin Laxity Treatment". Um total de 19 manuscritos foram incluídos em síntese qualitativa. Desenvolvimento: O MFU pode ser aplicado no tecido subcutâneo, produzindo pequenos pontos de coagulação térmica dentro da camada reticular média a profunda da derme e subderme. A aplicação de calor nesses discretos pontos de coagulação térmica faz com que haja neossíntese de colágeno e consequente enrijecimento da pele. Estudos recentes evidenciaramresultados promissores quanto a aplicação do MFU em regiões de sulco nasolabial, linha da mandíbula, sobrancelhas, região infraorbital, palpebra inferior e ligamentos de retenção zigomático-bucais. Considerações finais: O MFU tem se mostrado uma técnica segura, sendo considerado eficaz, não-invasiva, bem tolerada pelos pacientes e viável para a prática clínica médica e odontológica.


Introduction: The increase in average life expectancy leads the population to seek, with greater frequency, aesthetic treatments aimed at rejuvenating the face and neck. Microfocused ultrasound (MFU) is described as a non-invasive treatment option for facial sagging and aging. Objective: To review the scientific literature regarding the use of MFU in the process of facial rejuvenation and correction of sagging skin. Methodology: This is a narrative review of the literature, based on the search for scientific articles in the PubMed and Virtual Health Library databases carried out during the month of March 2022, using the following search strategy: "Microfocused Ultrasound AND Facial Rejuvenation AND Skin Laxity Treatment". A total of 19 manuscripts were included in a qualitative synthesis. Development: MFU can be applied to the subcutaneous tissue, producing small points of thermal coagulation within the middle to deep reticular layer of the dermis and subdermis. The application of heat to these discrete points of thermal coagulation causes collagen neosynthesis and consequent skin tightening. Recent studies have shown promising results regarding the application of MFU in regions of the nasolabial sulcus, jaw line, eyebrows, infraorbital region, lower eyelid and zygomatic-buccal retention ligaments. Final considerations: MFU has been shown to be a safe technique, being considered effective, non-invasive, well tolerated by patients and viable for clinical medical and dental practice.


Subject(s)
Rejuvenation , Ultrasonic Therapy , Skin Aging , Dentistry , Aesthetic Equipment , Face
5.
Braz. J. Anesth. (Impr.) ; 73(5): 626-634, 2023. tab, graf
Article in English | LILACS | ID: biblio-1520352

ABSTRACT

Abstract Background: The present study investigated the effects of pulsed and continuous ultrasound (USP and USC) in edema and hyperalgesia after chronic inflammatory process induced by Complete Freund's Adjuvant-CFA and analyzing the relationship of the application frequency of ultrasound, in pro- and anti-inflammatory cytokine production. Methods: Forty-five animals were divided into 9 groups; all animals from groups 2 to 9 were subjected to a persistent inflammation model induced by CFA in mice. We report the effects and the underlying action mechanisms of USP and USC in the animals which were irradiated two, three or five times a week on the left hind paw. The analyses performed in this study were: evaluation of hind paw edema through the plethysmometer, evaluation of thermal hyperalgesia through withdrawal test using a water container at 44.5°C (± 0.5°C), and the plantar region of the left paw which was removed for analysis of cytokines. Results: Our results showed that USP and USC consistently reduced paw edema, and pulsed ultrasound showed a higher significant effect than the continuous mode. Moreover, groups with irradiation frequency of five times a week presented an inhibition of the edema, and groups with frequency of three or two times a week reduced mainly hyperalgesia, in comparison with the control group. The beneficial effects of the US then seem to be associated with upregulation of anti- and pro-inflammatory mediators, such as IL-10 and IL-6, respectively. Conclusion: This study provided evidence that ultrasound constitutes an important non-pharmacological intervention for the management of inflammatory and pain states.


Subject(s)
Rats , Ultrasonic Therapy , Rehabilitation , Edema , Pain Management
6.
Braz. j. med. biol. res ; 56: e12576, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1447685

ABSTRACT

Type 2 diabetes mellitus (T2DM) is characterized by endothelial dysfunction that causes micro- and macrovascular complications. Low intensity therapeutic ultrasound (LITUS) may improve endothelial function, but its effects have not been investigated in these patients. The aim of our study was to compare the effects of pulsed (PUT) and continuous (CUT) waveforms of LITUS on the endothelium-dependent vasodilation of T2DM patients. The present randomized crossover trial had a sample of twenty-three patients (7 men) diagnosed with T2DM, 55.6 (±9.1) years old, with a body mass index of 28.6 (±3.3) kg/m2. All patients were randomized and submitted to different waveforms (Placebo, CUT, and PUT) of LITUS and the arterial endothelial function was evaluated. The LITUS of 1 MHz was applied in pulsed (PUT: 20% duty cycle, 0.08 W/cm2 SATA), continuous (CUT: 0.4 W/cm2 SPTA), and Placebo (equipment off) types of waves during 5 min on the brachial artery. Endothelial function was evaluated using the flow-mediated dilation (FMD) technique. PUT (mean difference 2.08%, 95% confidence interval 0.65 to 3.51) and CUT (mean difference 2.32%, 95% confidence interval 0.89 to 3.74) increased the %FMD compared to Placebo. In the effect size analysis, PUT (d=0.65) and CUT (d=0.65) waveforms presented moderate effects in the %FMD compared to Placebo. The vasodilator effect was similar in the different types of waves. Pulsed and continuous waveforms of LITUS of 1 MHz improved the arterial endothelial function in T2DM patients.

7.
Journal of Pharmaceutical Practice ; (6): 352-357, 2023.
Article in Chinese | WPRIM | ID: wpr-976526

ABSTRACT

Candida albicans is one of the most common species of Candida, which is an important cause of invasive candidiasis in clinic. Due to the frequently use of classical antifungal agents, there are amounts of drug resistant C. albicans being isolated, causing the significantly decreasing of the efficacy of some antifungal agents in clinical treatment. Besides, the use of some compounds in clinic has been limited because of their toxicities. In such a context, drug combination therapy shows great potential on antifungal because of the synergy of different drugs or therapeutic methods that could bring, which could improve the weaknesses of single drug.

8.
J. oral res. (Impresa) ; 11(1): 1-12, may. 11, 2022. ilus, tab
Article in English | LILACS | ID: biblio-1398536

ABSTRACT

Objective: This study aimed to compare the effect of ibuprofen and low intensity pulsed ultrasound (LIPUS) on the reduction of pain after the placement of initial archwire in orthodontic patients. Material and Methods: This double-blind clinical trial study was carried out on 60 female candidates for fixed orthodontic treatment referring to the Orthodontic Department of School of Dentistry in Mashhad University of Medical Sciences, Mashhad, Iran, during 2015-2016. The subjects were divided into four groups of ibuprofen, LIPUS, placebo, and mock LIPUS. A questionnaire and a rectangular and flexible cubic silicone were given to each patient to record the severity of pain based on the visual analog scale at specified time points (i.e., 2 h, 6 h, at bedtime, 2nd, 3rd, and 7th days after archwire placement) when biting the silicone block with the anterior and posterior teeth and without biting at all. Repeated measures analysis of variance was used in order to compare the pain severity at different time points. Results: The comparison of pain severity at various time points showed that the highest and lowest mean scores of pain were reported at bedtime and seven days after the intervention (p<0.001). In each of the three conditions (i.e., biting the silicone block with the anterior and posterior teeth and without biting the teeth) at six time points (i.e., 2 h, 6 h, at bedtime, 2nd, 3rd, and 7th days following archwire placement), no significant difference was observed in the severity of pain (p>0.05). Conclusion: In conclusion, LIPUS (with a frequency of 1 MHz and an intensity of 100 mW) and ibuprofen have no significant effects on reduction of the pain severity at different time points and various conditions in orthodontic patients.


Objetivo: Este estudio tuvo como objetivo comparar el efecto del ibuprofeno y el ultrasonido pulsado de baja intensidad (LIPUS) en la reducción del dolor después de la colocación del arco inicial en pacientes de ortodoncia. Material y Métodos: Este estudio de ensayo clínico doble ciego se llevó a cabo en 60 candidatas a tratamiento de ortodoncia fija referidas al Departamento de Ortodoncia de la Facultad de Odontología de la Universidad de Ciencias Médicas de Mashhad, Mashhad, Irán, durante 2015-2016. Los sujetos se dividieron en cuatro grupos: ibuprofeno, LIPUS, placebo y LIPUS simulado. Se entregó un cuestionario y un bloque de silicona cúbica rectangular y flexible a cada paciente para registrar la intensidad del dolor según la escala analógica visual en puntos de tiempo específicos (es decir, 2 h, 6 h, hora de acostarse, 2do, 3er y 7mo día después de la colocación del arco) al morder el bloque de silicona con los dientes anteriores y posteriores, y sin morder en absoluto. Se utilizó el análisis de varianza de medidas repetidas para comparar la intensidad del dolor en diferentes momentos.Resultados: La comparación de la intensidad del dolor en varios puntos de tiempo mostró que las puntuaciones medias de dolor más altas y más bajas se informaron a la hora de acostarse y siete días después de la intervención (p<0,001). En cada una de las tres condiciones (es decir, al morder el bloque de silicona con los dientes anteriores y posteriores, y sin morder) en seis momentos (2 h, 6 h, antes de acostarse 2do, 3er y 7mo día después de la colocación del arco), no se observó diferencia significativa en la severidad del dolor (p>0.05).Conclusión: En conclusión, LIPUS (con una frecuencia de 1 MHz y una intensidad de 100 mW) y el ibuprofeno no tienen efectos significativos en la reducción de la severidad del dolor en diferentes puntos de tiempo y diversas condiciones en pacientes de ortodoncia.


Subject(s)
Humans , Female , Child , Adolescent , Adult , Young Adult , Orthodontics , Ultrasonic Therapy , Facial Pain , Ibuprofen/administration & dosage , Orthodontic Wires/adverse effects , Pain Measurement , Double-Blind Method , Surveys and Questionnaires
9.
Rev. Assoc. Med. Bras. (1992, Impr.) ; 68(12): 1759-1764, 2022. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1422553

ABSTRACT

SUMMARY OBJECTIVE: This study aimed to compare the effects of therapeutic ultrasound and paraffin with or without vacuum massage on the biomechanical properties of grafted skin after a burn. METHODS: A total of 44 patients with deep second- and third-degree burns, with a mean age of 35.89 (±11.53) years, who visited the Hospital Burn Unity, were included in the study. The therapeutic interventions were randomly defined by drawing lots, with a crossover design (crossover), and a minimum interval of 7 days (washout) between interventions. Skin biomechanical parameters such as distensibility (R0) and viscoelasticity (R6) were noninvasively evaluated by Cutometer before and after 0, 10, 20, and 30 min of intervention with therapeutic ultrasound and paraffin alone, as well as associated with negative pressure therapy of the skin (vacuum therapy). In this study, all groups showed increased distensibility (R0) in the period immediately after the application of the resources and a progressive reduction in the effects in the consecutive tests. Participants with skin grafts showed a decrease in viscoelasticity (R6) in all groups, except therapeutic paraffin and therapeutic ultrasound and vacuum massage. CONCLUSION: The biomechanical properties of grafted skin after a burn are altered after therapeutic intervention with ultrasound alone or associated with vacuum massage, such as intervention with paraffin associated with vacuum massage, for both parameters evaluated, skin distensibility (R0) and skin viscoelasticity (R6). However, the same did not occur for the intervention with isolated paraffin. There was no significant difference between the interventions therapeutic ultrasound and therapeutic paraffin.

10.
Chinese Journal of Obstetrics and Gynecology ; (12): 259-264, 2022.
Article in Chinese | WPRIM | ID: wpr-932437

ABSTRACT

Objective:To investigate the relationship between the clinical efficacy and the ablated area of endometrium in patients with internal adenomyosis treated with focused ultrasound ablation surgery (FUAS).Methods:From January 2015 to December 2018, 122 patients in Chongqing Haifu Hospital who were diagnosed as internal adenomyosis through history, clinical symptoms and enhanced magnetic resonance imaging (MRI) and treated with FUAS were enrolled in this study. According to the patient′s wishes, patients were given whether to ablate the adenomyotic lesion alone or ablate the adenomyotic lesion and the endometrium that involved in adenomyotic lesions together. The ablated area of adenomyotic lesions and endomitrium were evaluated by post-FUAS enhanced MRI. The adverse events and the changes of dysmenorrhea and menstrual volume at different follow-up points within 24 months were recorded.Results:Among the 122 patients, 32 patients chose to ablate adenomyotic lesion alone, and 90 patients chose to ablate the adenomyotic lesion and the endometrium during FUAS. No major complications such as bowel injury and nerve injury occurred after FUAS. The median non-perfused volume ratio of adenomyotic lesions was 31.7% in the group without endometrial ablation and it was 60.0% in the group with endometrium ablation ( P<0.01). The improvement of dysmenorrhea in the group with endometrium ablation was significantly better than the group without endometrial ablation ( P<0.01). The average menstrual volume score (3.4±0.9) before FUAS in the group with endometrial ablation was higher than that in the group without endometrial ablation (2.5±0.6; P<0.01), but it decreased significantly after FUAS treatment, reaching the similar menstrual volume score of the group without endometrial ablation ( P>0.05). The proportions of abnormal vaginal discharge (34.4%, 31/90) and bleeding (16.7%, 15/90) were significantly higher in the group with endometrium ablation than those in the group without endometrial ablation (all P<0.01). Conclusions:FUAS could be safely and effectively used in the treatment of patients with internal adenomyosis. It seems that ablation of adenomyotic lesion and endometrium together could obtain better therapeutic effects.

11.
Fisioter. Mov. (Online) ; 34: e34112, 2021. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1249851

ABSTRACT

Abstract Introduction: In the rehabilitation of musculoskeletal injuries, ultrasound is widely used in clinical practice. Objective: To evaluate the effects of pulsed ultrasonic therapy on the viability and modulation of genes involved in inflammation (IL-6) and neovascularization (VEGF) processes of L929 fibroblast cells. Methods: For irradiation with ultrasound the cells were subdivided into groups: G1 (without irradiation), G2 (0.3 W/cm2-20%) and G3 (0.6 W/cm2-20%), with periods of treatment at 24, 48 and 72 hours. The cell viability assay was analyzed by the MTT method and gene modulation was analyzed by RT-qPCR method. Results: After the comparative analysis between groups, only G2 and G3 (48-hour) presented statistically significant differences in relation to the control. In relation to the gene expression, the selection of the groups analyzed was delimited according to the comparative analysis of the values obtained by the MTT test. After the achievement of RT-qPCR, it could be observed that in G2 the amount of VEGF gene transcripts increased by 1.125-fold compared to endogenous controls, and increased 1.388-fold in G3. The IL-6 gene, on the other hand, had its transcripts reduced in both G2 (5.64x10-9) and G3 (1.91x10-6). Conclusion: Pulsed ultrasound in L929 fibroblasts showed a significant biostimulatory effect in the 48-hour period, with increased cell viability, and the same effect in the modulation of gene expression related the neovascularization and inflammation, mediating the acceleration of the tissue repair cascade.


Resumo Introdução: Na reabilitação de lesões musculoesqueléticas, o ultrassom é amplamente utilizado na prática clínica. Objetivo: Avaliar os efeitos da terapia ultrassônica pulsada sobre a viabilidade e modulação de genes envolvidos nos processos de inflamação (IL-6) e neovascularização (VEGF) de fibroblastos L929. Métodos: Para irradiação com ultrassom, as células foram subdivididas em grupos: G1 (sem irradiação), G2 (0,3 W/cm2-20%) e G3 (0,6 W/cm2-20%), com períodos de tratamento de 24, 48 e 72 horas. O ensaio de viabilidade celular foi analisado pelo método MTT e a modulação gênica pelo método RT-qPCR. Resultados: Após a análise comparativa entre os grupos, apenas G2 e G3 (48 horas) apresentaram diferenças estatisticamente significantes em relação ao controle. Em relação à expressão gênica, a seleção dos grupos analisados ​​foi delimitada de acordo com a análise comparativa dos valores obtidos pelo teste MTT. Após a obtenção do RT-qPCR, pôde-se observar que no G2 a quantidade de transcritos do gene VEGF aumentou 1,125 vezes em relação aos controles endógenos e 1,388 vezes no G3. O gene IL-6, por outro lado, teve seus transcritos reduzidos tanto no G2 (5,64x10-9) quanto no G3 (1,91x10-6). Conclusão: O ultrassom pulsado em fibroblastos L929 apresentou efeito bioestimulador significativo no período de 48 horas, com aumento da viabilidade celular, e o mesmo efeito na modulação da expressão gênica relacionou neovascularização e inflamação, mediando a aceleração da cascata de reparação de tecidos.

12.
Braz. oral res. (Online) ; 35: e008, 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1132748

ABSTRACT

Abstract: The aim of this study was to assess the influence of micro-computed tomography (micro-CT) voxel size on the evaluation of debris accumulation after passive ultrasonic irrigation (PUI) in curved root canals prepared with rotary nickel-titanium files. Mesial root canals (n = 24) of mandibular molars with curvature between 25° and 35° were prepared using ProDesign Logic 30/.05 (PDL) or HyFlex EDM 25/.08 (HEDM). PUI was performed after root canal preparation of all root canals. The specimens were scanned using high-resolution (5 μm voxel size) micro-CT imaging before and after experimental procedures. The percentage of debris was analyzed in the middle and apical thirds using images with 5, 10 and 20 μm voxel sizes. Data were compared using unpaired and paired Student's t-test, ANOVA and Tukey's statistical tests (α = 0.05). There were no differences among the debris analyses performed at different voxel sizes (5, 10 and 20 μm) (p > 0.05). The percentage of debris was similar between the root canals prepared by PDL and HEDM before and after PUI (p > 0.05). In both groups, the percentage of debris decreased in the middle third after PUI (p < 0.05). Within the limitations of this ex vivo study, it can be concluded that the voxel sizes evaluated did not have a significant impact on the analysis of accumulated debris. However, the results showed a tendency for detection of more debris in the analysis performed using a lower voxel size. PUI decreased the debris accumulation in the middle third of curved root canals.


Subject(s)
Humans , Root Canal Preparation , Dental Pulp Cavity/diagnostic imaging , X-Ray Microtomography , Molar/diagnostic imaging
13.
Int. j. morphol ; 38(5): 1288-1295, oct. 2020. tab, graf
Article in English | LILACS | ID: biblio-1134438

ABSTRACT

SUMMARY: The aim of this study was to evaluate the effects of stretching and therapeutic ultrasound (TUS) on desmin and laminin contents of rat muscle after contusion. Male Wistar rats (n = 35, 8-9 weeks of age, 271 ± 14g body weight) were divided into five groups: Control group (CG) (n= 03); Injured group (IG) (n= 8); Injured + ultrasound group (IUSG) (n= 8); Injured+stretching group (ISG) (n= 8); Injured +ultrasound + stretching group (IUSSG) (n= 8). The application of ultrasound started 72 hours after the contusion, using the 50 % pulsed mode, 0.5 W/cm2, 5 min, once a day, for five consecutive days. Passive manual stretching was started on the tenth day after injury, with four repetitions of 30 s each and 30 s rest between repetitions, once a day, five times per week, for a total of ten applications. After 22 days, the rats were euthanazied and the gastrocnemius of both limbs removed for desmin and laminin immunohistochemistry morphometric measurement. Analysis was conducted using ANOVA one way post-hoc Tukey to parametric data and Kruskall-Wallis for non-parametric data. The IUSSG animals showed a larger area of desmin than ISG (p<0.05). It was found a decrease in laminin comparing IUSG to IG. However, laminin area was higher in ISG than all groups (p<0.05). UST isolated or in combination with stretching influenced gastrocnemius regeneration in different manners. While stretching applied isolated enhanced gastrocnemius regeneration noticed by the increase in laminin area, in combination with TUS strengthened the muscle healing rising desmin area.


RESUMEN: El objetivo de este estudio fue evaluar los efectos del estiramiento y la ecografía en los contenidos de desmina y laminina del músculo de rata después de la lesión. Ratas Wistar macho (n = 35, 8-9 semanas de edad, 271 ± 14 g de peso corporal) se dividieron en cinco grupos: grupo de control (CG) (n = 03); Grupo lesionado (GL) (n = 8); Lesionado + grupo de ultrasonido (LGU) (n= 8); Lesionado + grupo de estiramiento (LGE) (n = 8); Lesionado + ultrasonido + grupo de estiramiento (LUGE) (n = 8). La aplicación de ultrasonido comenzó 72 horas después de la lesión, usando el modo pulsado al 50 %, 0,5W / cm2, 5 min, una vez al día, durante cinco días consecutivos. El estiramiento manual pasivo se inició el décimo día después de la lesión, con cuatro repeticiones de 30 seg cada una y 30 seg de descanso entre repeticiones, una vez al día, cinco veces por semana, para un total de diez aplicaciones. Las ratas fueron sacrificadas después de 22 días, y se extrajo el músculo gastrocnemio de ambos miembros para la medición morfométrica de desmina y laminina a través de inmunohistoquímica. El análisis se realizó utilizando ANOVA unidireccional Tukey post-hoc para datos paramétricos y Kruskall-Wallis para datos no paramétricos. Los animales LUGE mostraron un área mayor de desmina que LGE (p <0,05). Se encontró una disminución en la laminina comparando LGU con GL. Sin embargo, el área de laminina fue mayor en LGE que en todos los grupos (p <0,05). El tratamiento con ultrasonido aislado o en combinación con estiramiento influyó en la regeneración del músculo gastrocnemio de diferentes maneras. Si bien el estiramiento aplicado, en combinación con tratamiento de ultrasonido, fortaleció el área de desmina, la regeneración del músculo gastrocnemio mejoró por el aumento en el área de laminina aumentando la curación muscular.


Subject(s)
Animals , Male , Rats , Ultrasonic Therapy/methods , Muscle, Skeletal/pathology , Contusions/therapy , Muscle Stretching Exercises/methods , Immunohistochemistry , Analysis of Variance , Laminin/analysis , Rats, Wistar , Muscle, Skeletal/injuries , Desmin/analysis
14.
RFO UPF ; 25(2): 291-302, 20200830. tab
Article in Portuguese | LILACS, BBO | ID: biblio-1357805

ABSTRACT

Objetivo: revisar a literatura quanto ao uso de soluções no reservatório líquido do ultrassom (US) para o tratamento das doenças periodontais, avaliando as contribuições dessa associação e as soluções mais eficazes para essa terapêutica. Métodos: foi realizada pesquisa bibliográfica nas bases de dados Public Medline (PubMed), Lilacs, Science Direct e ISI web of knowledge. As palavras-chave utilizadas foram: "periodontal disease", "ultrasonic", "cooling solution", "antimicrobial" e "irrigation". Como critérios de inclusão, foram selecionados estudos prospectivos, retrospectivos, caso controle, transversal e relatos de casos, publicados em inglês. Resultados: após pesquisa e minuciosa revisão por título e resumo de cada estudo, 15 estudos foram selecionados para avaliação dos desfechos investigados. As principais soluções associadas ao US foram povidono-iodo (PVPI), clorexidina, óleos essenciais, bicarbonato de sódio. O irrigante mais utilizado foi o PVPI, seguido por clorexidina e óleos essenciais. Os agentes podem conferir discretas melhoras no nível clínico de inserção e profundidade de sondagem, porém os resultados são controversos, já que nem todos os ensaios demonstraram efeitos positivos. Uma importante evidência observada foi em relação à redução dos níveis de microrganismos derivados do aerossol do US quando essas substâncias foram utilizadas no reservatório de água, sendo esse um aspecto positivo de seu uso como solução refrigerante ao US. Considerações finais: de modo geral, não puderam ser confirmados benefícios adicionais dos irrigantes antimicrobianos nos principais parâmetros periodontais avaliados, porém não se pode descartar o potencial uso desses agentes para a redução da dispersão de microrganismos advindos do aerossol, promovendo assim maior proteção ao paciente e ao profissional.(AU)


Objective: to review the literature regarding the use of solutions in the liquid ultrasonic (US) reservoir devices for the treatment of periodontal diseases, evaluating the benefits of this association, and the most effective solution for this therapy. Methods: bibliographic research was carried out in the Public Medline (PubMed), Lilacs, Science Direct, and ISI web of knowledge databases. The keywords used were: "periodontal disease", "ultrasonic", "cooling solution", "antimicrobial", and "irrigation". Inclusion criteria were prospective, retrospective, case-control, cross-sectional studies, and case reports published in English. Results: after a meticulous analysis of each paper by title and summary, 15 studies were selected for further investigation of clinical outcomes. The main solutions associated with US devices as coolant were PVPI, Chlorhexidine, Essential Oils and Sodium Bicarbonate. The most used coolant agent was PVPI, followed by chlorhexidine and essential oils. It has been shown that irrigating solutions can provide improvements in the clinical attachment level and probing depth, but the results are controversial since not all trials showed positive effects. Important evidence observed was the reduction of the levels of microorganisms derived from the US aerosol when these substances were used as a cooling solution. Conclusions: in general, additional benefits of coolant solutions could not be confirmed in the main periodontal parameters evaluated, however, the potential use of these agents to reduce the dispersion of microorganisms derived from the aerosol cannot be ruled out, thus promoting additional protection to the patient and professional.(AU)


Subject(s)
Humans , Periodontal Diseases/therapy , Ultrasonic Therapy/methods , Anti-Infective Agents/therapeutic use , Povidone-Iodine/therapeutic use , Oils, Volatile/therapeutic use , Chlorhexidine/therapeutic use , Sodium Bicarbonate/therapeutic use , Cooling Agents
15.
Fisioter. Pesqui. (Online) ; 27(2): 202-209, abr.-jun. 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1133928

ABSTRACT

ABSTRACT Studies have described the use of electrophysical agents (EPA) by physical therapists worldwide. However, the use of EPA by Brazilian physical therapists remains undetermined. This study aims to describe the availability, use, and perception about EPA by orthopedic and sports physical therapists in Brazil. Professionals of the area were invited to answer an online questionnaire. Demographic data and information regarding the availability, use and perception about EPA in their current clinical practice were asked. Out of 376 physical therapists included in this study, 89% declared to use EPA in clinical practice. Sensory electrotherapy with pulsed current (TENS), therapeutic ultrasound, excitomotor electrotherapy with pulsed current (FES/NMES), and cryotherapy are available for more than 3/4 of interviewees. Scientific articles and clinical experience, respectively, are the most influential factors for the choice of EPA. Ultrasound is the most frequently used EPA, followed by TENS, cryotherapy, photobiomodulation, hot packs, and FES/NMES. The top-five most useful EPA in clinical practice chosen by physical therapists are: (1) ultrasound; (2) photobiomodulation; (3) TENS; (4) cryotherapy; and (5) FES/NMES. In conclusion, EPA are widely used by orthopedic and sports physical therapists in Brazil. Therapeutic ultrasound, TENS, FES/NMES, photobiomodulation, cryotherapy, and hot packs are the most used EPA in clinical practice of these physiotherapists.


RESUMO Estudos têm descrito a utilização de agentes eletrofísicos (AE) por fisioterapeutas ao redor do mundo. No entanto, o uso de AE por fisioterapeutas brasileiros permanece inexplorado. O objetivo deste estudo é descrever o acesso, a utilização e a percepção sobre os AE de fisioterapeutas ortopédicos e esportivos no Brasil. Os profissionais foram convidados a responder um questionário on-line. Foram solicitados dados demográficos e informações sobre o acesso, utilização e percepção dos profissionais sobre os AE na prática clínica. Dentre os 376 fisioterapeutas incluídos, 89% declararam ser usuários de AE na prática clínica. Eletroterapia sensorial com corrente pulsada (TENS), ultrassom terapêutico, eletroterapia excitomotora com corrente pulsada (FES/NMES) e crioterapia são acessíveis para mais de 3/4 dos participantes. Artigos científicos e experiência clínica são os fatores de maior influência na escolha por AE. O ultrassom é o AE mais frequentemente utilizado, seguido por Tens, crioterapia, fotobiomodulação, bolsas quentes e FES/NMES. Os cinco AE elencados pelos fisioterapeutas como mais úteis na prática clínica são: (1) ultrassom; (2) fotobiomodulação; (3) TENS; (4) crioterapia; e (5) FES/NMES. Em conclusão, os AE são largamente usados pelos fisioterapeutas ortopédicos e esportivos no Brasil. Ultrassom terapêutico, TENS, FES/NMES, fotobiomodulação, crioterapia e bolsas quentes são os AE mais usados na prática clínica desses fisioterapeutas.


RESUMEN Los estudios ya han descrito el uso de agentes electrofísicos (AE) por fisioterapeutas en todo el mundo. Todavía no se ha explorado el uso de los AE por fisioterapeutas brasileños. El presente estudio tuvo como objetivo describir el acceso, el uso y la percepción sobre los AE por fisioterapeutas ortopédicos y deportivos en Brasil. Se invitó a los profesionales para responder a un cuestionario en línea. Se solicitaron los datos demográficos e informaciones sobre el acceso, el uso y la percepción de profesionales sobre los AE en la práctica clínica. Entre los 376 fisioterapeutas incluidos, el 89% declararon utilizar los AE en la práctica clínica. La electroterapia sensorial con corriente pulsada (TENS), el ultrasonido terapéutico, la electroterapia excitomotora con corriente pulsada (FES/NMES) y la crioterapia son accesibles para más de 3/4 de los participantes. Los artículos científicos y la experiencia clínica son los factores que más influyeron en la elección de los AE. El ultrasonido es el AE más utilizado, seguido de Tens, crioterapia, fotobiomodulación, bolsas calientes y FES/NMES. Los cinco AE más útiles en la práctica clínica enumerados por los fisioterapeutas fueron: (1) ultrasonido; (2) fotobiomodulación; (3) TENS; (4) crioterapia; y (5) FES/NMES. Los AE son ampliamente utilizados por los profesionales de la ortopedia y el deporte en Brasil. El ultrasonido terapéutico, TENS, FES/NMES, fotobiomodulación, crioterapia y bolsas calientes son los AE más utilizados en la práctica clínica por estos fisioterapeutas.

16.
Fisioter. Bras ; 21(2): 204-210, Mai 16, 2020.
Article in Portuguese | LILACS | ID: biblio-1282972

ABSTRACT

Introdução: As associações de Terapias Combinadas de Ultrassom e Eletroterapia (TCUE) no mercado nacional podem ser utilizadas através de diferentes equipamentos. Na prática clínica tem-se relatado que o uso das TCUE tem eficácia no tratamento da adiposidade localizada. Objetivo: Avaliar os efeitos da terapia combinada (TCUE) no tratamento da adiposidade localizada. Métodos: Trata-se de um estudo experimental, composto por uma amostra de 15 coelhos, de ambos os sexos, da espécie Oryctolagus Cuniculus, divididos aleatoriamente em três grupos: G1- grupo TCUE-M que utilizou efeitos do ultrassom com aplicação de correntes estereodinâmicas (n = 5); G2- grupo TCUE -H que utilizou uma combinação de ultrassom e corrente Aussie (n = 5) e G3- controle (n = 5) nenhuma terapia. Resultados: As análises dos resultados revelaram pequenas alterações na camada adiposa na maioria dos coelhos integrantes dos grupos tratados. Conclusão: A análise das lâminas histológicas apresentou irregularidades na membrana celular adiposa mostrando diferentes tamanhos de células. (AU)


Introduction: Associations of Combined Ultrasound Therapy and Electrotherapy (TCUE) can be used in the domestic market through different equipment. Some authors report that the use of TCUE has efficacy in the treatment of localized adiposity. Objective: To evaluate the effects of combined therapy (TCUE) in the treatment of localized adiposity. Methods: This is an experimental study consisting of a sample of 15 rabbits of both sexes of the species Oryctolagus Cuniculus, randomly divided into three groups: G1- TCUE-M group that used ultrasound effects with the application of stereodynamic currents (n = 5); G2-TCUE-H group that used a combination of ultrasound and current Aussie (n = 5) and G3-control (n = 5) no therapy. Results: Analyzes of the results revealed small alterations in the adipose layer in most of the rabbits in the treated groups. Conclusion: Analysis of the histological slides presented irregularities in the adipose cell membrane showing different cell sizes. (AU)


Subject(s)
Humans , Combined Modality Therapy , Adiposity , Ultrasonic Therapy , Adipose Tissue , Electric Stimulation Therapy
17.
Chinese Journal of Medical Imaging Technology ; (12): 1388-1391, 2020.
Article in Chinese | WPRIM | ID: wpr-860920

ABSTRACT

The incidence of gynecological malignant tumors is increasing year by year, posing serious threatens to women's health. Photoacoustic dynamic therapy includes photodynamic therapy and sonodynamic therapy, killing tumor cells by photosensitizer and sonosensitizer activated by light or ultrasound, have the advantages of non-invasion, precise targeting, little side effects and widely used in diagnosis and treatment of gynecological tumors. The progress of photoacoustic dynamic therapy and its application in cervical cancer, ovarian cancer and endometrial cancer were reviewed in this article.

18.
Chinese Journal of Urology ; (12): 157-160, 2020.
Article in Chinese | WPRIM | ID: wpr-869617

ABSTRACT

Low-intensity pulsed ultrasound (LIPUS) is a form of ultrasound that delivered at a much lower intensity (< 3 W/cm2) than traditional ultrasound and output in the mode of pulse wave,it is typically used for therapeutic purpose in rehabilitation medicine.It has minimal thermal effects due to its low intensity and pulsed output mode,and its non-thermal effects which is normally claimed to induce therapeutic effect in tissues attracting much attentions.LIPUS have been demonstrated to have a rage of biological effects on tissues,including accelerating soft-tissue regeneration,promoting bone-fracture healing,inhibiting inflammatory responses,etc.Hopefully,LIPUS may become an effective clinical procedure for the treatment of urological diseases,such as chronic prostatitis/chronic pelvic pain syndrome (CP/CPPS),erectile dysfunction (ED),and stress urinary incontinence (SUI).It still needs an intense effort for basic and clinical investigators to explore the biomedical applications of microenergy medicine.

19.
Braz. j. med. biol. res ; 52(2): e7773, 2019. tab, graf
Article in English | LILACS | ID: biblio-984030

ABSTRACT

The aim of this study was to evaluate the therapeutic effects of ultrasound (US)-mediated phonophoresis alone or in association with diclofenac diethylammonium (DCF) administered topically in animal models of inflammation. A pre-clinical, prospective, and randomized experimental study of quantitative and qualitative nature was carried out. Phonophoresis was performed using a therapeutic ultrasound apparatus in two distinct models of acute inflammation. Edema was induced by an intraplantar injection of carrageenan and measured by plethysmography. The Hargreaves test was used to evaluate the antinociceptive activity and investigate the action of phonophoresis on tumor necrosis factor (TNF)-α production. A histological analysis with hematoxylin-eosin was used to evaluate tissue repair, and the expression of COX-2 was determined by immunohistochemical analysis. At the peak of inflammatory activity (3 h), treatment with US, US+DCF, and DCF significantly reduced edema formation compared to the control group. Treatment with US+DCF was more effective than treatment with US alone at both analyzed times. In the analysis of the antinociceptive activity, the treatments significantly increased the latency time in response to the thermal stimulus. Histopathological analysis revealed a reduction of the inflammatory infiltrates and immunohistochemistry demonstrated that the association was effective in reducing COX-2 expression compared to the control group. The association of DCF with US produced anti-inflammatory and antinociceptive effects in rat models of inflammation, which may be associated with inhibition of COX-2 and TNF-α production.


Subject(s)
Animals , Male , Rats , Phonophoresis , Anti-Inflammatory Agents, Non-Steroidal/administration & dosage , Diclofenac/administration & dosage , Analgesics/administration & dosage , Inflammation/drug therapy , Anti-Inflammatory Agents/administration & dosage , Ultrasonic Therapy/methods , Random Allocation , Prospective Studies , Administration, Topical , Tumor Necrosis Factor-alpha , Rats, Wistar , Disease Models, Animal , Inflammation/physiopathology , Inflammation/pathology
20.
Chinese Journal of Interventional Imaging and Therapy ; (12): 485-490, 2019.
Article in Chinese | WPRIM | ID: wpr-862099

ABSTRACT

Objective: To analyze the effect and mechanism of low intensity ultrasound on bone marrow suppression induced by docetaxel in rat models. Methods: Forty female rats were randomly divided into ultrasound group and control group (each n=20). Daily intraperitoneal injection of docetaxel (25 mg/kg) was given all rats for consecutive 4 days. Rats in ultrasound group were daily irradiated with low intensity ultrasound for consecutive 7 days after the first injection of docetaxel, while rats in control group received false irradiation at the same time. Routine blood examination and immunoglobulin tests were performed before docetaxel injection on the 4th, 7th and 14th day of irradiation. On the 4th day of irradiation, 4 rats in each group were randomly selected and killed for detection of stem cell factor (SCF), intercellular adhesion molecule-1 (ICAM-1) and vascular cell adhesion molecule-1 (VCAM-1). Histological methods were used to detect the number of nucleated cells in the right femoral bone marrow tissue of rats before injection of docetaxel on the 4th, 7th and 14th day after the first time of irradiation. HE staining and pathological examinations of skin and muscle tissues of rats were performed on the 7th day after the first time of irradiation. Results: In ultrasound group, leukocyte, neutrophil and lymphocyte counts in peripheral blood on the 4th day after the first time of irradiatio, titer of immunoglobulin A (IgA) on the 7th and 14th day after the first time of irradiation, titers of immunoglobulin G (IgG) and immunoglobulin M (IgM) on the 4th and 14th day after the first time of irradiation increased obviously compared with those of control group (all P<0.05). The relative mRNA expression levels of SCF and ICAM-1 in bone marrow of rats in ultrasound group were significantly higher than those in control group, while the relative mRNA expression level of VCAM-1 in bone marrow of rats in ultrasound group was significantly lower than that in control group (all P<0.05). On the 4th and 7th day after the first time of irradiation, the numbers of bone marrow nucleated cells in ultrasound group were significantly higher than those in control group (both P<0.05). There was no obvious damage to the skin and muscle of the irradiated rats in both the two groups. Conclusion: Low intensity ultrasound is feasible in treatment of bone marrow suppression induced by docetaxel in rats, and its mechanism may be improvement of bone marrow hematopoietic microenvironment.